- Bridging the Terahertz Gap
- Modeling the Lithium-Ion Battery
- Protection contre la Corrosion
- Modélisation des batteries
- Modélisation et Simulation dans le développement des piles à combustible
- Modélisation thermique des petits satellites
- Analyse électro-vibroacoustique d'un transducteur à armature équilibrée
Consultez les proceedings de la Conference COMSOL 2024
Manuel Collet is a member of the Department of Applied Mechanics of the FEMTO-ST Institute. He graduated with a degree in Mechanical Engineering from Ecole Centrale de Lyon in 1992 and obtained his PhD in 1996 about Active control of vibrating structures by mean of semi distributed ... En savoir plus
A recurring problem, in heat assisted magnetic recording is the build-up of thermal energy in the near-field transducer leading to NFT deformation and the cessation of operation. A mechanism to dissipate this excess heat in the NFT without greatly effecting its’ plasmonic response is ... En savoir plus
A three-dimensional finite element model, based on the linear field equations for superimposed small vibrations onto nonlinear thermoelastic stressed media given by Lee and Yong, was developed. This method involves solving the thermal stress and piezoelectric model with geometric and ... En savoir plus
When placing a loudspeaker in a cabinet, standing waves inside the cabinet affect the frequency response with ripples. This peaks and dips due to pressure cancellation inside the cabinet have an effect on the diaphragm and generating sound out from the vents. If it was in a condition of ... En savoir plus
MEMS Pressure sensors work on the principle of mechanical bending of thin diaphragm under applied load over diaphragm area. The sensitivity of diaphragm is crucial to efficiency of the sensor. It is defined as the increase in deflection of diaphragm as a result of increase in pressure ... En savoir plus
Finite element (FE) modelling of ultrasonic propagation using COMSOL Multiphysics® simulations can be used to create images of waves. Unfortunately, in time-stepping solutions, it is possible for numerical instabilities to grow large and dominate the solution adversely. Any design of ... En savoir plus
Capacitive MEMS sensors offer high spatial resolution, sensitivity and good frequency response. In this paper, we present a circular membrane capacitive MEMS device that finds use both as capacitive micromachined ultrasonic transducer (CMUT) and pressure sensor. The MEMS device is first ... En savoir plus
High frequency ultrasound (100-1000 MHz) has been used in microscopy since the 1970s. The main imaging component, the acoustic lens, is commercially available. The resolution, working distance, and focal length depend on the structure of a lens, which is unique for each produced lens. ... En savoir plus
The paper presents a method of extraction of coupling of modes (COM) parameters for a one port surface acoustic wave (SAW) resonator from the results of finite element analysis in COMSOL Multiphysics®. The COM parameters calculated are electromechanical coupling coefficient, reflection ... En savoir plus
Daily application of a low intensity pulsed ultrasound (LIPUS) regimen has been shown to have positive effects on bone fracture healing. Although LIPUS treatment can induce cellular responses supporting bone repair, the underlying mechanisms are not well understood. Further in vitro ... En savoir plus