- Bridging the Terahertz Gap
- Modeling the Lithium-Ion Battery
- Protection contre la Corrosion
- Modélisation des batteries
- Modélisation et Simulation dans le développement des piles à combustible
- Modélisation thermique des petits satellites
- Analyse électro-vibroacoustique d'un transducteur à armature équilibrée
Consultez les proceedings de la Conference COMSOL 2024
MEMS Pressure sensors work on the principle of mechanical bending of thin diaphragm under applied load over diaphragm area. The sensitivity of diaphragm is crucial to efficiency of the sensor. It is defined as the increase in deflection of diaphragm as a result of increase in pressure ... En savoir plus
A three-dimensional finite element model, based on the linear field equations for superimposed small vibrations onto nonlinear thermoelastic stressed media given by Lee and Yong, was developed. This method involves solving the thermal stress and piezoelectric model with geometric and ... En savoir plus
Finite element (FE) modelling of ultrasonic propagation using COMSOL Multiphysics® simulations can be used to create images of waves. Unfortunately, in time-stepping solutions, it is possible for numerical instabilities to grow large and dominate the solution adversely. Any design of ... En savoir plus
IntroductionThe application of power ultrasounds in food dehydration processes have shown a good performance in terms of efficiency, energy reduction and quality of the final product, allowing also a reduction in the convective drying kinetics, and at lower temperatures than conventional ... En savoir plus
Capacitive MEMS sensors offer high spatial resolution, sensitivity and good frequency response. In this paper, we present a circular membrane capacitive MEMS device that finds use both as capacitive micromachined ultrasonic transducer (CMUT) and pressure sensor. The MEMS device is first ... En savoir plus
The paper presents a method of extraction of coupling of modes (COM) parameters for a one port surface acoustic wave (SAW) resonator from the results of finite element analysis in COMSOL Multiphysics®. The COM parameters calculated are electromechanical coupling coefficient, reflection ... En savoir plus
High frequency ultrasound (100-1000 MHz) has been used in microscopy since the 1970s. The main imaging component, the acoustic lens, is commercially available. The resolution, working distance, and focal length depend on the structure of a lens, which is unique for each produced lens. ... En savoir plus
Position sensors have several applications in the automotive sector. Some of the common examples include automatic gear shifter module, seat position adjustment and accelerator-pedal position modules etc. Because of extreme weather condition, such as dust, humidity and moisture and ... En savoir plus
Daily application of a low intensity pulsed ultrasound (LIPUS) regimen has been shown to have positive effects on bone fracture healing. Although LIPUS treatment can induce cellular responses supporting bone repair, the underlying mechanisms are not well understood. Further in vitro ... En savoir plus
In the field of electronic, electro-acoustic apparatus is one of the important applications. There is an acoustic class in the department of electronic engineering, Shibaura Institute of Technology. The class is “Acoustic systems” which opens in 2nd semester of 3rd year. To foster the ... En savoir plus