Determination and Verification of the Forchheimer Coefficients for Ceramic Foam Filters using COMSOL CFD Modeling
Publié en  2012
                        Experiments have been conducted with water at velocities from ~0.015-0.77 m/s to determine the permeability of 50 mm thick commercially available 30, 40, 50 and 80 Pores Per Inch (PPI) Ceramic Foam Filters (CFF) used for liquid metal filtration. Measurements were made using two different setups, for use with the Forchheimer equation: 49 mm \"straight through\" and 101 mm diameter \"expanding flow field\" designs. 2D axial symmetric CFD modeling with COMSOL Multiphysics 4.2a showed that the two equipment designs delivered equivalent permeability data. In so doing it has been shown that COMSOL gives model results with
                        Téléchargement
- kennedy_presentation.pdf - 1.27MB
 - kennedy_paper.pdf - 0.38MB
 - kennedy_abstract.pdf - 1.88MB
 