Consultez les proceedings de la Conference COMSOL 2024
3D model of MEMS based SAW gas sensor is designed using Focused Inter Digital Transducers design. Surface displacement & Electrical potential are analyzed at resonance & anti-resonance frequencies. Operating frequency is from 8.7 MHz which acts as start band and 9.2 MHz as stop ... En savoir plus
Optical tweezers work on the idea of non-contact Optical Pressure felt by transparent particles, when shined by coherent light source such as lasers. On the other hand when light falls on the metal it excites the electron inside it and make them free. When these free electron cloud ... En savoir plus
Pressure-driven air flow is directed over the microfluidic cavity induces circulating fluid motion in the cavity. Analyte contained in the air stream is absorbed into the cavity, mixes with the nanoparticles as a result of the circulating cavity flow. Therefore, the nanoparticles ... En savoir plus
Finite element models for acoustic scattering from three dimensional underwater elastic objects, calculated in the frequency domain, are transformed to the time domain through Fourier synthesis using COMSOL Multiphysics®. The time domain mirrors the way in which experimental scattering ... En savoir plus
This paper presents numerical simulation of plate wave modes in thin stainless steel plates using a racetrack spiral coil electromagnetic acoustic transducer (EMAT), which works under the principle of acousto-elastic effect, called Lorentz force mechanism. EMATs are useful for non ... En savoir plus
FEM (Finite Element Method) modelling software such as COMSOL Multiphysics® can be a powerful tool for modelling the behavior and response of piezoelectric materials and devices [1]. Devices based on piezoelectric crystals are particularly well suited, because the polarization magnitude ... En savoir plus
Due to the increasing demand for hydrogen gas sensors for applications such as automation, transportation, or environmental monitoring, the need for sensitive and reliable sensors with a short response time is increasing. This paper presents an empirical model that studies the ... En savoir plus
The technique of water calorimetry for primary-standard dosimetry of radiotherapy-level ionizing radiation is well established at national metrology institutes around the world, where such a direct realization of absorbed dose establishes the basis for calibrating instruments used for ... En savoir plus
Surface acoustic wave (SAW) devices are widely used for their sensing capabilities and gas sensing is only one of many uses. There is an ever increasing need to make them as effective as possible by adding nanomaterials to the device. In this study a two-port delay-line structure with ... En savoir plus
To maintain same droplet size across parallel devices, new break-up strategies based on geometry are been studied. In this work, we model a geometrically-set droplet generator, in which the droplet break-up occurs by a block and break mechanism. In other words when the disperse phase ... En savoir plus