- Bridging the Terahertz Gap
- Modeling the Lithium-Ion Battery
- Protection contre la Corrosion
- Modélisation des batteries
- Modélisation et Simulation dans le développement des piles à combustible
- Modélisation thermique des petits satellites
- Analyse électro-vibroacoustique d'un transducteur à armature équilibrée
Consultez les proceedings de la Conference COMSOL 2024
The performance of a homogeneous T-mixer can be enhanced significantly by the stimulation of secondary/ transverse flows in the microchannel. Various mixing mechanisms are reported for enhancing micromixing performance such as grooves at the channel bottom, heterogeneous charge patterns ... En savoir plus
This paper presents a simulation of the operation of a new type of droplet generation probe. This probe, consisting of two concentrically-arranged tubings, is immersed in a beaker of cell medium so that oil is pumped through the outer tubing at a pumping speed less than fluid is drawn ... En savoir plus
Finite element analysis has been used to model the ultrasonic wave propagation both in a custom made transducer and in the tested polymer sample. The model consists of acoustic (passive elements) and electroacoustic (active elements) transmission lines. The simulation of the acoustic ... En savoir plus
Capacitive MEMS (Micro-Electro-Mechanical Systems) accelerometers may be directly soldered to the printed circuit board by an array of solder balls. Differences in the thermal expansion coefficients of the pertinent materials cause deformations of the accelerometer under temperature ... En savoir plus
In this conference we have brought together a community that is scientifically diverse in an event that allows for inspiring contacts about the use of COMSOL Multiphysics. It is an event to connect with the Spanish and Portuguese COMSOL Multiphysics users and participate in training ... En savoir plus
This work aims to investigate the behaviour of a simple interdigital sensor structure for glucose monitoring in response to distortions in the skin-topology and differences in skin undulation during use. The study then extends to consider a flexible sensor structure which is better able ... En savoir plus
In this work perforated microring resonator based refractive index sensor is presented. Numerical analysis of the microring using COMSOL Multiphysics® was performed. From transmission spectra sensitivity and quality factor of our proposed structure were evaluated. It was shown that ... En savoir plus
In our project, we propose an innovative software solution to the problem of electrical arcing risk prediction in high-voltage on-board electronic equipment intended for long-term self-contained use, e.g. in spacecraft conditions. It completely based on so-called “decomposition” approach ... En savoir plus
A dual axis MEMS seismometer targeted for building monitoring system has been simulated for a full scale of ±5g acceleration. The design uses the capacitive effect for vibration sensing. This comb drive capacitive MEMS seismometer consists of 8 springs with two proof masses. The device ... En savoir plus
The optimal orientations of different single-photon detector designs were determined by COMSOL software package. Absorption of niobium-nitride (NbN) stripes in two different (p=220 nm, 3p=660 nm) periodic patterns integrated with plasmonic elements was studied. In OC-SNSPDs consisting ... En savoir plus