Quick Search

Peristaltic Pump

Application ID: 985


In a peristaltic pump, rotating rollers squeeze a flexible tube. As the rollers move along the tube, the fluid in the tube follows the motion. The main advantage of the peristaltic pump is that no seals, valves or other internal parts ever touch the fluid. Due to their cleanliness, peristaltic pumps have found many applications in the pharmaceutical, chemical, biomedical and food industries.

This COMSOL Multiphysics model of a peristaltic pump is a combination of structural mechanics (to model the squeezing of the tube) and fluid dynamics (to compute the fluid’s motion); that is, this is an example of fluid-structure interaction (FSI).

This model also shows some analysis features. Integration coupling variables are defined for the flow computations and for evaluating the inside volume of the tube. An ordinary differential equation is also used for calculating the accumulated flow.

This model is included as an example in the following products:

Structural Mechanics Module

The combination of COMSOL® products required to model your application depends on several factors and may include boundary conditions, material properties, physics interfaces, and part libraries. Particular functionality may be common to several products. To determine the right combination of products for your modeling needs, review the Grille de spécifications and make use of a free evaluation license. The COMSOL Sales and Support teams are available for answering any questions you may have regarding this.